Features:
- Sterilization temperature can be set up to 138 degrees
-Adopt PT1000 sensor for more precise temperature control with 0.1 degree display accuracy
- Two water level monitoring functions: capacitive water level sensor and temperature type water level sensor
- With 5-level password setting function, it can be used for data trace of pharmaceutical companies, meet GMP and FDA certification requirements, and can print FO value.
SMS alarm (optional)
Configurable negative pressure to a pressure gauge up to 0.5
- Standard optimization to prevent dry burning
-Open the cover to stop heating
- Real-time data saving function, memory storage 60 programs, programmable various mode sterilization programs
- voice prompt function
-Intelligent multi-stage exhaust function
-Freertos embedded operating system
- Standard U disk real-time data recording and download function
-Log function (touch screen)
- Fault monitoring, alarm and recording functions (touch screen)
- With automatic detection, check the relationship between temperature and pressure to ensure a true saturated steam state
-Automatically detect cold air emissions, ensure steam internal discharge function, and ensure pollution-free environment
-The boiling temperature can be adjusted according to the altitude
- Exhaust gas temperature can be adjusted within 0-25 degrees of boiling temperature
- Dual temperature sensor for detecting temperature and water temperature
- One sensor hole and one verification hole for the tank cover, convenient for verifying the connection
|
Product advantages |
|
Inner row After cooling, the steam is discharged through a professional condenser to achieve true internal discharge and prevent environmental pollution.
cooling fan Automatic start of sterilization, optimized design of the three-dimensional condensing fan to the overall cooling of the liner, shortening the cooling time
|
Easy to operate:
Display accuracy:
0.1 sterilization stage graphic display The opening temperature can be adjusted according to the customer's demand below 95 °C. |
Internal electrochemical polishing:
Electrochemical polishing after blasting the inner liner to reduce the area of bacterial adhesion, anti-fouling residue, convenient for users to clean and maintain |
Dry burning protection:
Standard low water level sensor and heating rate software program to effectively prevent dry burning |
High efficiency filter:
0.2um HEPA college filter with filter function to achieve zero pollution |
Many advantages, sterilization is safer and more thorough
STIK provides you with high quality sterilizers, always adhering to the "safety first" purpose
Safety
Pressure chain - Start-up, sterilization start, micro-motion position switch in real-time during sterilization Monitor the location of the chain office to ensure safety once there is an abnormal alarm. - As long as there is pressure in the chamber (with pressure sensor), the lid cannot be opened. - The lid cannot be opened when the power is suddenly turned off during the sterilization process. - After the sterilization is completed, the opening temperature can be arbitrarily set within the chamber temperature below 95 °C. |
-Double overpressure protection -Double over temperature protection -Double exhaust solenoid valve - Prevent dry burning -Pressure Sensor -leakage protector -Full automatic intelligent control system |
Capacity (L) / model | Diameter 370 standard | Diameter 450 standard | Automatic hydration type | Dry type | Deodorizing type | Leading touch screen |
54 liters | IMJ-54A | |||||
78liters | IMJ-78A | |||||
65liters | IMJ-65A | MJ-65W | IMJ-65D | IMJ-65S | IMJ-65DT | |
85liters | IMJ-85A | MJ-85W | IMJ-85D | IMJ-85S | IMJ-85DT | |
100liters | IMJ-100A | IMJ-100W | IMJ-100D | IMJ-100S | IMJ-1000T | |
120liters | IMJ-120A | IMJ-120W | IMJ-120D | IMJ-120S | IMJ-1200T | |
Inner tube electropolishing | Have | Have | Have | Have | Have | Have |
Liner material | 3 | 3 | 3 | 3 | 3 | 3 |
Display accuracy | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
Sterilization maximum setting temperature | 138 | 138 | 138 | 138 | 138 | 138 |
Gas cylinder | Side setting | Side setting | Inside setting | Inside setting | Inside setting | Inside setting |
Sterilization range (°) | 105-138 | |||||
Dissolution temperature (°) | 50-100 | |||||
Holding temperature (°) | 40-60 | |||||
Set time | Sterilization, melting: 0 minutes - 9999 minutes; holding time: 9999 hours; scheduled sterilization time: 0-15 days delay | |||||
Storage System | ||||||
Pressure display range | -0.1-0.5mpa | |||||
Exhaust method | Full row, micro row, no row, intelligent multi-stage exhaust | |||||
Safety equipment | Pressure safety valve, prevent dry burning, door lock safety interlock device, chamber cover closing detection system, over pressure detection, over temperature detection, leakage short circuit detection | |||||
Automatic hydration | No | No | Have | Have | Have | Have |
Dry | No | No | No | Have | No | Have |
Internal row function | No | No | No | No | Have | Have |
Deodorization system | No | No | No | No | Have | Have |
Cooling fan | Horizontal row | Vertical row | Vertical row | Vertical row | Vertical row | Vertical row |
Water level sensing | Have | Have | Have | Have | Have | Have |
Pressure Sensor | Have | Have | Have | Have | Have | Have |
USB | Have | Have | Have | Have | Have | Have |
Pan opening method | One-touch upper cover | |||||
Dimensions(W*D*H)mm | 612*520*840 612*520*1070 815*660*985 815*660*1125 815*660*1230 815*660*1365 | |||||
Dimensions | 5-45℃ | |||||
Volume (liter) | 54 | 78 | 65 | 85 | 100 | 120 |
Rated power | 2800W | 3500W | 3500W | 4800W | 4800W | 4800W |
Sterilization bile size (diameter * high) | Φ370*508 | Φ370*730 | Φ450*465 | Φ450*605 | Φ450*710 | Φ450*845 |
Basket size(W*D*H)mm | Φ340*190*2 | Φ340230 Φ340*350 |
Φ430*190*2 | Φ430*230*2 | Φ430*230 Φ430*350 |
Φ430*350*2 |
Product weight | 79KG | 120kg | 110kg | 145kg | 180kg | 216kg |
Overall dimensions (W * D * H) mm |
612*520*840 | 612*520*1070 | 815*660*985 | 815*660*1125 | 815*660*1230 | 815*660*1365 |
Working power | 220V±10%,16A,50HZ/60HZ | 220V±10%,32A,50HZ/60HZ |
-The test technical data is only applicable to the test results under the no-load condition of the equipment and the ambient temperature is 25 degrees!
-The appearance and parameters of the product are subject to change without notice. The appearance of the product may vary due to photography and printing. Please understand!
-Printer (printing content: pressure in the pot during sterilization, sterilization temperature and time)
- item sensor
-3Q certification
-All internal rows